§ 19B-7. Minimum freeboard.
(a)
No Person shall design, construct, operate, use, or maintain an engineered containment structure for impoundment of recycled water unless said Recycled Water Pond is designed to maintain and unless said Person maintains a Freeboard of not less than two (2) feet as measured from the lowest rim of the Recycled Water Pond.
(b)
Freeboard calculations shall meet the following parameters:
(1)
Recycled Water Ponds shall be sized so as to withstand a one hundred (100) year rainfall return year followed by a normal rainfall year without overflow; and
(2)
Recycled Water Ponds, other than those that have been permitted by Use Permits to remain full year- round, shall be sized so as to be drained completely prior to the subsequent rainfall year.