§ 19B-9. Minimum setbacks.
No Person shall construct, operate, use, or maintain a Recycled Water Pond unless the following setbacks are maintained as measured from the toe of the pond:
(a)
One hundred (100) feet to ten (10) year floodplain (high water mark) or floodway;
(b)
One hundred (100) feet to individual or public water system well;
(c)
One hundred (100) feet to lake or domestic water supply reservoir;
(d)
One hundred (100) feet to perennial stream;
(e)
Two hundred (200) feet to perennial stream in watershed protection district;
(e)
Fifty (50) feet to ephemeral stream; and
(f)
Fifty (50) feet to property line (greater separation may be required through Use Permit).